- Make sure pressure regulator screws are released (turned out) on both tanks.
- Standing to the side of the regulator, Slowly open the oxygen cylinder valve fully
- Standing to the side of the regulator, Slowly open the Acetylene cylinder valve ¼ turn
- With the welding or cutting adjustment valves open, quickly adjust the working pressure to the desired amount